Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Microbiol Methods ; 96: 1-5, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24184312

RESUMO

The objective of this study was to compare an extraction-based sampling method to two vacuum-based sampling methods (vacuum sock and 37mm cassette filter) with regards to their ability to recover Bacillus atrophaeus spores (surrogate for Bacillus anthracis) from pleated heating, ventilation, and air conditioning (HVAC) filters that are typically found in commercial and residential buildings. Electrostatic and mechanical HVAC filters were tested, both without and after loading with dust to 50% of their total holding capacity. The results were analyzed by one-way ANOVA across material types, presence or absence of dust, and sampling device. The extraction method gave higher relative recoveries than the two vacuum methods evaluated (p≤0.001). On average, recoveries obtained by the vacuum methods were about 30% of those achieved by the extraction method. Relative recoveries between the two vacuum methods were not significantly different (p>0.05). Although extraction methods yielded higher recoveries than vacuum methods, either HVAC filter sampling approach may provide a rapid and inexpensive mechanism for understanding the extent of contamination following a wide-area biological release incident.


Assuntos
Filtros de Ar/microbiologia , Bacillus/isolamento & purificação , Técnicas Bacteriológicas/métodos , Manejo de Espécimes/métodos , Esporos Bacterianos/isolamento & purificação
2.
J Microbiol Methods ; 95(3): 389-96, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24184017

RESUMO

In this study, four commonly-used sampling devices (vacuum socks, 37 mm 0.8 µm mixed cellulose ester (MCE) filter cassettes, 37 mm 0.3 µm polytetrafluoroethylene (PTFE) filter cassettes, and 3M™ forensic filters) were comparatively evaluated for their ability to recover surface-associated spores. Aerosolized spores (~10(5)CFUcm(-2)) of a Bacillus anthracis surrogate were allowed to settle onto three material types (concrete, carpet, and upholstery). Ten replicate samples were collected using each vacuum method, from each material type. Stainless steel surfaces, inoculated simultaneously with test materials, were sampled with pre-moistened wipes. Wipe recoveries were utilized to normalize vacuum-based recoveries across trials. Recovery (CFUcm(-2)) and relative recovery (vacuum recovery/wipe recovery) were determined for each method and material type. Recoveries and relative recoveries ranged from 3.8 × 10(3) to 7.4 × 10(4)CFUcm(-2) and 0.035 to 1.242, respectively. ANOVA results indicated that the 37 mm MCE method exhibited higher relative recoveries than the other methods when used for sampling concrete or upholstery. While the vacuum sock resulted in the highest relative recoveries on carpet, no statistically significant difference was detected. The results of this study may be used to guide selection of sampling approaches following biological contamination incidents.


Assuntos
Bacillus anthracis/isolamento & purificação , Técnicas Bacteriológicas/métodos , Microbiologia Ambiental , Manejo de Espécimes/métodos , Esporos Bacterianos/isolamento & purificação , Vácuo , Contagem de Colônia Microbiana
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...